1.2.two Warning Labels Warning Labels Which means Be sure to diligently read this handbook prior to use product. The following labels are a. Tend not to place the product with a sloped surface. Normally the accessible if the system unit may well slide, leading to private personal injury or the unit is effective with the cell malfunction.

iZoom™ enables accurate viewing of graphic from length iWorks™ Protocol helps standardize workflow and minimize exam moments

Klik Setuju dan Lanjutkan untuk menyetujui cookie dan langsung menuju ke situs atau klik Informasi Selengkapnya untuk melihat deskripsi element mengenai tipe cookie dan memilih apakah akan menyetujui cookie tertentu saat berada di situs ini.

Permits use of several scanned angles to form a single image, causing Increased contrast resolution and enhanced visualization

The chapter provides the method to verify most important perform and efficiency of merchandise. This is often only used for reference, not preventive execution. Perform checking and tests of this element shall be carried out by Mindray services engineers as well as the user together. Web site 66: Basic Test

Will not use any cables other than the cables presented Using the system by Mindray. three. Make use of the cable delivered with this system to attach the printer. Other cables may lead to electric shock. Webpage 15: Mechanical Safety

Dengan obshape baru yang cerdas dan desain layar penuh, mobilitas yang ditingkatkan, dan pengoperasian yang lebih nyaman, sistem yang andal dan terjangkau ini akan meningkatkan praktik umum dan sangat cocok untuk berbagai kebutuhan klinis.

5.two.3 Geometric positioning precision Longitudinal geometric positioning accuracy  Exam Action: Do adjustments as the way in tests the maximum depth. File the distance by 20mm each section around the longitudinal targets line utilizing the measurement caliper; Pick the worth with the greatest error (to 20mm), calculate the accuracy utilizing the formulation down below The measurement caliper must be positioned on the higher fringe of the target, Observe:... Web page seventy nine Transverse geometric positioning precision  Test Phase: Include the scan floor from the phantom with drinking water or few gel, Carefully Get in touch with the probe with the scan surface Alter the depth, earning the transverse targets to become shown from the graphic. Regulate the focus stage to get posited beside the transverse targets (the conventional isn't very clear) Change parameters like get, TGC, making Every transverse targets for being Obviously displayed. Page eighty 5.five.two.4 Blackout Area Test Phase: Protect the scan surface area from the phantom with h2o or couple gel, gently contact the probe With all the scan area Change the depth in a lessen price, and established the main focus at the closest location to the scan surface. Lower the value of parameters like AP, Gain right up until the history sound just can be viewed. Webpage eighty one: Program Improve Dp50rb login And Maintenance

Notice: Before uploading the log, ensure the ultrasound program continues to be linked to network, usually, the system could alert “couldn't hook up with server” The server (smtp.

Just after changing the CPU module, essential file need to be produced Once more in accordance with the new MAC tackle and written into HDD of your equipment. Or else, the configuration operate on the solution is going to be misplaced. Following taking away the CPU module, Get rid of panhead screws with washers (twelve M3X6) fixed on the principle device box, you may take off the board. Site 118 Determine eight-29 Disassemble the User interface Assembly (one) Keep the higher edge of control panel assembly, and open up up the user interface. Figure 8-30 Disassemble the User interface Assembly (two) Right after removing just one countersunk head self-tapping screw PT3X10 mounted on the user interface and get out the plug with the keyboard and the primary unit connecting cables, you might take out the user interface assembly.

Return to the program preset interface. The option status improvements into Uninstalled. The uninstalling functionality is exceptional to interior users.

Mindray’s new generation of black & white ultrasound procedure, DP-50 Qualified, is equipped with Highly developed imaging technologies making it possible for further penetration and quicker graphic acquisition with larger resolution.

Lower off cable ties connecting the main unit over the Screen by diagonal slicing pliers, then pull out the corresponding cable plugs.

Content material Strategy Examine the battery periodically : a) Test if battery is often charged Usually when electric power-on: That The present potential is one hundred% or potential increases just after a brief time implies the battery might be billed Generally.